Wednesday, 08 April 2020 08:52

Water Test Kit

- Have POTTER test the water supply of the sprinkler system
- Meets requirements of NFPA 13, 2002 4.3
- 5 groups of bacteria tested

Part#Potter#
404099 WTK

Additional Files

Click on the buttons inside the tabbed menu:

Sales Sheets

Other Documents

Wednesday, 08 April 2020 08:51

Corrosion Monitoring Station

- Service pressure: up to 250 PSIG
- Temperature range: 40°F to 120°F (4.5°C to 49°C)
- Coupon Holders: Qty. (2) included
- Designed to simulate conditions within the fire sprinkler system
- The coupon rack can be isolated from the fire sprinkler riser and easily accessed for servicing and monitoring of test specimens (corrosion coupons) without interruption to fire protection

Part#Potter#
404042 PCMS-RM

Additional Files

Click on the buttons inside the tabbed menu:

Sales Sheets

Other Documents

Wednesday, 08 April 2020 08:50

Automatic Air Release

- Service pressure: up to 175 PSIG
- Temperature range: 40°F to 120°F (4.5°C to 49°C)
- Air Vent: 1” NPT inlet 3/32” Orifice
- Water Shutoff Valve: Activation indicated by red pop-up tap on the shutoff valve
- Single set of NC contacts rated 24V AC/DC @2A ( contacts open upon activation of shutoff valve) and 6' Lg. Wiring harness supplied for supervision of shutoff valve

Part#Potter#
404091 PAAR-B

Additional Files

Click on the buttons inside the tabbed menu:

Other Documents

Wednesday, 08 April 2020 08:47

Pressure Switch – Adjustable Deadband

Potter Flow

image image
 

- The model PCS is an Adjustable Deadband Pressure Switch with independent set and reset points which are adjustable throughout the entire operating range of the switch
- The minimum deadband (minimum span between set and reset points) may be obtained at any point in the operating range of the switch
- A change in pressure greater than the high setting will reposition the switch mechanism to open or close a single snap-action electrical switch
- This control device is designed for use as an operating control in applications sensing air, water, or any fluid not harmful to the pressure connection, diaphragm or nitrile pressure-sealing o-ring.
- Where an operating control would result in personal injury and-or loss of property, it is the responsibility of the installer to add devices (safety, limit controls) that protect against, or systems (alarm, supervisory systems) that warn of control failure
- Not intended for applications in explosive environments or use with hazardous fluids
- Adjustable Pressure Switch
Minimum deadband: 12 PSIG
Proof pressure: 400 PSIG
Factory setting: 90/60 PSIG

Part#Potter#Description
404085 PCS-300-1B Single

Additional Files

Click on the buttons inside the tabbed menu:

Sales Sheets

Other Documents

Wednesday, 08 April 2020 08:46

Switch – Pressure, Excess Pressure

Potter Flow

image image image
 

- Pressure actuated switches designed primarily to detect a 10 PSI increase and/or decrease from normal system pressure in automatic fire sprinkler systems
- Typical applications are air pressure supervision in systems with excess pressure
- PS120-1A: Operates on decrease at 110 PSI
- PS120-2A: Operates on increase at 130 PSI and on decrease at 110 PSI
- Pressure Range: 10-175 PSI

Part#Potter#Description
4071120 PS120-1A Single
4071120 - 2A PS120-2A Double

Additional Files

Click on the buttons inside the tabbed menu:

Other Documents

Wednesday, 08 April 2020 08:44

Switch – Pressure, Dry Systems

Potter Flow

image image image
 

- Pressure actuated switches designed primarily to detect a 10 PSI increase and/or decrease from normal system pressure in automatic fire sprinkler systems
- Typical applications are air pressure supervision in dry pipe systems and pressure supervision of pressure tanks, air supply or water supply
- PS40-1A: Operates on decrease at 30PSI
PS40-2A: Operates on increase at 50 PSI, and on decrease at 30 PSI
Pressure Range: 10-175 PSI

Part#Potter#Description
407140 PS40-1A Single
407140 - 2A PS40-2A Double

Additional Files

Click on the buttons inside the tabbed menu:

Other Documents

Wednesday, 08 April 2020 08:43

Switch – Low Pressure, Wet Systems

Potter Flow

image image image
 

- The Potter PS10A Series Pressure Actuated Switches are designed for the detection of a waterflow condition in automatic fire sprinkler systems of particular designs such as wet systems with alarm check valves or dry pipe systems
- May also be used to provide a low pressure supervisory signal
- They may be adjusted to operate on pressure between 4 and 20 PSI

Part#Potter#Description
407110 PS10-1A Single
407110 - 2A PS10-2A Double

Additional Files

Click on the buttons inside the tabbed menu:

Other Documents

Wednesday, 08 April 2020 08:41

Key – for Tamper Proof Cover Screws

Part#Potter#
4070TK for cover screws
4070WK for PMS & PTS switches only
Wednesday, 08 April 2020 08:40

Switch – Waterflow Alarm

Potter Flow

image image image
 

- Pressure operated switch with an adjustable, instantly recycling pneumatic retard to prevent false alarms due to water pressure variation
- The EFSR-F is connected into the alarm port of a wet sprinkler system alarm check valve
Pressure Adjustments: Factory adjusted to operate between 4 and 8 PSI on rising pressure
Maximum System Pressure: 175 PSI
Contact Ratings: Two Sets of SPDT (Form C)

Part#Potter#
404076 WFSR-F

Additional Files

Click on the buttons inside the tabbed menu:

Sales Sheets

Other Documents

Wednesday, 08 April 2020 08:38

Switch – Flow, CPVC

 

- The Model VSR-SFT is a vane type waterflow switch for use on wet sprinkler systems that use 1”, 1-1/4”, 1-1/2” pip size
- It is equipped with a union to accommodate installation in confined spaces
- Contains two single pole double throw snap action switches and an adjustable, instantly recycling pneumatic retard
- The switches are actuated when a flow of 8-10 gallons per minute (30-38 liters per minute) or more occurs downstream of the device
- The flow condition must exist for a period of time necessary to overcome the selected retard period
- For 1” to 2” CPVC pipe sizes with NEMA 4 enclosure indoor & outdoor use, service pressure to 175 PSI

Part#Potter#TypeSize
40761 VSR-SFG glue in union 1” - 2”
40762 VSR-SFT threaded 1” - 2”

Additional Files

Click on the buttons inside the tabbed menu:

Sales Sheets

Other Documents

Page 26 of 40