Home:Products»FDC and Cabinets»Super User
Friday, 08 May 2020 07:53

Extended Screw Down Guard

- Heavy wire construction
- Mounts directly to ceiling or wall with wire eyelets
- Use with two-piece pendant (skirt & cup) escutcheons
- Use with dry head applications
- 4 ½” wide by 6” deep
- White powder coated finish
- Fasteners not included

Part#
305688SD
Tuesday, 05 May 2020 07:53

Inspector Test and Shut Off

 
image image
 

- Inspector Test & Drain Valve
- Brass valve in 1” & 1-1/4” sizes
- Test, Drain, and shut off valve
- Teflon Seats
- Acrylic Sight Glass
- Orifice size 1/2” is standard and stocked units
- cULus and FM approved

Part#Size
8087100 1”
8087114 1-1/4”

Additional Files

Click on the buttons inside the tabbed menu:

Techanical Informaiton

Other Documents

Tuesday, 05 May 2020 07:31

AGF Testandrain

 
image image image image
 

85112 Model 1000

85112 Model 1000

 

85212 Model 1011A

85212T Model 1011T

 

- Provides the test and express drain function in a multi story installation, for a wet fire sprinkler system
- Tamper resistant test orifice, sight glass
- Rated 300 PSI
- Orifice size 1/2” is standard and stocked units
- Other orifice sizes are available

Part#DescriptionSize
85112 Model 1000 1”
85122 Model 1000 1-1/4”
85132 Model 1000 1-1/2”
85142 Model 1000 2”
85142G Model 1000 2” G x G
85212 Model 1011A 1”
85222 Model 1011A 1-1/4”
85232 Model 1011A 1-1/2”
85244 Model 1011A 2”
85212T Model 1011T 1”
85222T Model 1011T 1-1/4”
85232T Model 1011T 1-1/2”
85244T Model 1011T 2”

Additional Files

Click on the buttons inside the tabbed menu:

Techanical Informaiton

Other Documents

Tuesday, 05 May 2020 04:43

Air Maintenance Device H2 & H3

Compressor Use – Model H-2 and Model H-3

image image
 

- Automatic, field-adjustable devices that control the on-off cycling of and air compressor
- Utilized in applications where it is desirable or necessary to use a small no-tank mounted compressor that is to be dedicated to the system to be pressurized
- The H-2 and H-3 monitor system pressure and automatically cycle the air compressor on and off to maintain system pressure within the preset limits
- Model H-2 used with air compressors with an unloader as an integral part.
- As pressure on the system side of the 1/4” check valve drops, the air pressure switch contacts close, causing the compressor to start
- Model H-3 is used when the primary air compressor is not equipped with an unloader device

Part#Description
G320595 Model H-2
G320600 Model H-3

Additional Files

Click on the buttons inside the tabbed menu:

Sales Sheets

Other Documents

Tuesday, 05 May 2020 04:37

Air Maintenance Device H1

Independent Air System – Model H-1

image image
 

- Globe's Model H-1 Air Pressure Maintenance Device is an automatic, field-adjustable device of the pressure reducing type
- The H-1 is utilized in applications where there is a compressed air (or nitrogen) source which is at a higher pressure than the desired system pressure

Part#Description
G320585 Model H-1

Additional Files

Click on the buttons inside the tabbed menu:

Sales Sheets

Other Documents

Tuesday, 05 May 2020 04:31

Water Motor Gong

 
image image
 

- Hydraulically operated indoor and outdoor alarms
- Used with alarm check, dry pipe, deluge, and preaction valves to sound a local alarm
- Eliminates the need for an electrical alarm
- Provides an audible fire alarm both inside and outside the building
- Suitable for mounting to any type of rigid wall to thickness up to 16” (406.4mm)
- Includes a listed and approved strainer for use in the alarm line
- Fabricated from corrosion resistant cast aluminum
- The polymer drive bearings do not require lubrication

Part#Description
G325500 WM, single gong system
G324430 WM2, two gong system
G315515 30” long drive shaft only

Additional Files

Click on the buttons inside the tabbed menu:

Sales Sheets

Other Documents

Tuesday, 05 May 2020 04:24

Accelerator

 
image image
 

- Used to reduce the time lag normally associated with the opening of a Dry Pipe Valve after one or more system sprinklers have operated
- Accelerates the opening of the Dry Pipe Valve
- Monitors the air pressure in a Dry Pipe System
- The Anti-Flooding Device is included with orders for the Model C

Part#Description
G300400 Model C with anti-flooding device
G300465-2 Accelerator trim F3, G3 for dry pipe valve
G318526 Accelerator trim model D, for dry pipe valve

Additional Files

Click on the buttons inside the tabbed menu:

Sales Sheets

Other Documents

Tuesday, 05 May 2020 04:21

Wet Alarm Valves Repair Kits

- All kits are used with model H-1, H-2 and H-3
- Each kit includes a rubber disc and cover gasket

Part#Description
G323802 3”
G323502 4” 
G323562  6” 
G323832  8” 
Tuesday, 05 May 2020 04:13

Dry Pipe Valve Repair Kits

- Gasket kits for the repair of Globe's dry pipe valves

Kit Part#Kit DescriptionItems included partItems included description
G319750 4” dry pipe valve Model F G300002 Diaphragm
    G300005 Rubber seat ring
    G300023 Cover plate gasket
    G300030 Gasket
    G300028 Gasket
G319751 4” dry pipe valve Model F-2 G319754 Bellofram
    G300005 Rubber seat ring
    G300023 Cover plate gasket
    G300030 Gasket
    G319758 Shield
G319752 4” dry pipe valve Model F-3 and G-3 G319794 Bellofram
    G319791 Rubber seat ring
    G300023 Cover plate gasket
    G300030 Gasket
    G319758 Shield
G319800 6” dry pipe valve Model F G300202 Diaphragm
    G300205 Rubber seat ring
    G300219 Cover plate gasket
    G300030 Gasket
    G300028 Gasket
G319801 6” dry pipe valve Model F-2 G319804 Bellofram
    G300205 Rubber seat ring
    G300219 Cover plate gasket
    G300030 Gasket
    G319808 Shield
G319803 6” dry pipe valve Model F-3 and G-3 G319844 Bellofram
    G319841 Rubber seat ring
    G300219 Cover plate gasket
    G300030 Gasket
    G319808 Shield
Tuesday, 05 May 2020 04:08

Dry Alarm Valves

 
image image image
 

 

- Globe's RCW water control valve for dry, preaction and deluge applications
- cULus and FM approved
- 4" and 6" size and up to 10 different trim configurtions
- Shorter and lighter than past models
- Grove x Grove ends, 300 PSI working pressure
- Less trim, with trim or pre trimmed options
- See data sheet for a variety of pre trimmed options for RCW valve

Valve OnlyTrim OnlyPre Trimmed ValveSize
G317400 G317340-4 G317448B 4”
G317550 G317340-6 G317493B 6”

Additional Files

Click on the buttons inside the tabbed menu:

Page 5 of 40